ISSN: 1003-6326
CN: 43-1239/TG
CODEN: TNMCEW

Vol. 18    No. 3    June 2008

[PDF]    
Corrosion behavior of Mg and Mg-Zn alloys in simulated body fluid
GAO Jia-cheng(高家诚)1, 2, WU Sha(伍 沙)1, QIAO Li-ying(乔丽英)1, 2, WANG Yong(王 勇)1
(1. College of Materials Science and Engineering, Chongqing University, Chongqing 400044, China;2. National Engineering Research Center for Magnesium Alloy, Chongqing University, Chongqing 400044, China)
Abstract: The corrosion behavior of Mg and Mg-Zn in simulated body fluid was studied. The mass loss of pure Mg, Mg-Zn-Zr and Mg-Zn-Zr-Y in simulated body fluid was measured using photovoltaic scale meter. Corrosion rate was determined through electrochemical tests. Finally, the corrosion mechanism was thermodynamically studied. The results show that the corrosion rate decreases with the lapse of time for both pure Mg and Mg alloys. The purer the alloy, the better the corrosion resistance exhibits. The corrosion behavior of Mg alloy is improved by the addition of trace Y.
Key words: Mg alloy; bio-compatibility; corrosion resistance
Superintended by The China Association for Science and Technology (CAST)
Sponsored by The Nonferrous Metals Society of China (NFSOC)
Managed by Central South University (CSU) 湘ICP备09001153号-9