ISSN: 1003-6326
CN: 43-1239/TG
CODEN: TNMCEW

Vol. 16    Special 2    September 2006

[PDF]    
Ultrahigh performance of Ti-based glassy alloy tube sensor for Coriolis mass flowmeter
马朝利1,A. Inoue2,张涛3
(1.北京航空航天大学 材料科学与工程学院 空天材料与服役教育部重点实验室,北京1001912.Institute for Materials Research, Tohoku University, Sendai 980-8577, Japan3.Key Laboratory of Silicate Materials Science and Engineering of Ministry of Education,Wuhan University of Technology, Wuhan 430070, China)
Abstract: Bulk metallic glasses (BMGs) have potential applications for both structural and functional components owing to their good mechanical properties. With the aim of demonstrating great engineering value of BMGs, a direct melt-forming technique based on suction casting for the production of glassy alloy tubes was developed. The fabrication, structure, geometry, properties and sensor performance of the tubes were examined. The results show that the Coriolis mass flowmeters using the Ti-based glassy alloy sensor tube exhibit excellent measurement sensitivity, viz. 28.5 times higher than that of the conventional flowmeter manufactured using stainless steel (SUS316) tube.
Key words: glassy alloy tube; sensor; performance; Coriolis mass flowmeter
Superintended by The China Association for Science and Technology (CAST)
Sponsored by The Nonferrous Metals Society of China (NFSOC)
Managed by Central South University (CSU) 湘ICP备09001153号-9