Mining, Minerals Processing and Metallurgical Engineering

Influence of temperature on acoustic emission source location accuracy in underground structure

Expand
  • Long-jun DONG, Qing TAO, Qing-chun HU
School of Resources and Safety Engineering, Central South University, Changsha 410083, China

Online published: 2021-08-25

Abstract

An acoustic emission (AE) experiment was carried out to explore the AE location accuracy influenced by temperature. A hollow hemispherical specimen was used to simulate common underground structures. In the process of heating with the flame, the pulse signal of constant frequency was stimulated as an AE source. Then AE signals received by each sensor were collected and used for comparing localization accuracy at different temperatures. Results show that location errors of AE keep the same phenomenon in the early and middle heating stages. In the later stage of heating, location errors of AE increase sharply due to the appearance of cracks. This provides some beneficial suggestions on decreasing location errors of structural cracks caused by temperature and improves the ability of underground structure disaster prevention and control.

Cite this article

Long-jun DONG, Qing TAO, Qing-chun HU . Influence of temperature on acoustic emission source location accuracy in underground structure[J]. Transactions of Nonferrous Metals Society of China, 2021 , 31(8) : 2468 -2478 . DOI: 10.1016/S1003-6326(21)65667-4